SeaDataNet Common Data Index (CDI)

The selected data set is described below with metadata. Access to the data set itself can be requested via the SeaDataNet portal that gives an overview and access to marine and ocean data sets acquired and managed by European organisations. Go to: https://www.seadatanet.org

Details

What?
Data set nameVolvo Ocean Race AkzoNobel 2021
Discipline
Parameter groups
Discovery parameter
GEMET-INSPIRE themesOceanographic geographical features
AbstractThe provided microplastic dataset was generated during The Ocean Race Europe in May-June 2021. The samples were collected onboard two 65’ one-design yachts known as VolvoOcean65, called AmberSail2 and AkzoNobel Ocean Racing in the Baltic Sea, North Atlantic Ocean and Mediterranean Sea. During the race and delivery periods, a total of 36 microplastic samples were taken by filtering seawater through two stainless steel filters with 100 and 500 µm meshes. Only the 500 µm are analysed in this dataset. The samples were typically taken 0.5–1.5 meter below the sea surface, although this is dependent on sea-state and heel, being representative of the mixed-layer microplastic concentration, rather than the microplastics floating on the surface. The water supply was from one of two inlets located at each side of the yachts bottom; the leeward intake was always used to avoid air contamination in the system. Some water for the yacht’s water maker supply was diverted to the filtration system and an analytical system (OceanPack™Race by SubCtech GmbH) that also measured salinity, temperature and partial pressure of carbon dioxide (pCO2). The OceanPack continuously logged the position during sampling, as well as the volume of sampled water from a flowmeter located at the filtration unit. The filters were exchanged at variable intervals during the delivery and race periods due to competitive constraints which resulted in a range of sampling-times and volumes. The average time between filter change was ~12h (min 2h, max 22h) and the sampled volume for each sample averaged at 0.37 m³ (min 0.05m³ max 0.7m³). After sampling, these filters were securely packed and transported to the lab in Kiel to be measured for their microplastic concentration after sampling. In a laboratory under filtered air (DB1000, HEPA filtration, Q = 950 m³/h, Mo¨cklinghoff Lufttechnik; Bergmann et al., 2017), each filter was transferred to a glass beaker and the inside of the bag rinsed into the beaker with 0.2 µm-filtered ultrapure water (18.2 MOhm-cm; MilliQ, Millipore). The filter was sonicated in an ultrasonic bath for 15 minutes to remove particles, and the filter removed from the beaker and rinsed. The remaining suspension was then filtered onto a glass-fiber filter (GF/F; Whatman) under gentle vacuum, and filters air-dried and stored in glass petri dishes. Plastic fragments and fibers were identified visually under magnification by personnel trained on reference particles down to 20 µm in size. Plastic items were transferred to glass mounting slides for imaging, size measurement, and polymer identification by near-infrared hyperspectral imaging (Beck et al., in prep). This method has a practical size detection limit of about 100 µm, but reliable measurement is limited by the narrowest particle dimension. Unfortunately, the particles found in the current study were too small to give clearly identifiable spectra for polymer identification. Work is ongoing to improve detection limits for small particles. Note the presented analysis focuses on the 500 um filter data as particles on the 100 um filter are too small for the hyperspectral camera. The methods employed allowed separating microplastic fibers and fragments which is a new feature with respect to the last sampling campaign and Raman measurements (Tanuha et al., 2020).
Data format
Data set creation date20230802
Where?
Map
© OpenStreetMap contributors
GML idmc01
GML objects
NameDescription
1Transect 1
2Transect 2
3Transect 3
DatumWorld Geodetic System 84
Measuring area typecurve
Depth referencemean sea level
Minimum instrument depth (m)0.5
Maximum instrument depth (m)1.5
Sea regions
Location qualificationBoth (Landward + beyond the 12 NM boundary)
Ices areas
  • Bay of Biscay and the Iberian Coast
  • Western Mediterranean Sea
MSFD areas
  • Mediterranean Sea
  • North East Atlantic Ocean
Ospar areasBay of Biscay and Iberian Coast
When?
Start date20210517
Start time00:00:00
End date20210524
End time00:00:00
How?
Instrument/gear category
Device type
Platform type
Cruise nameAkzoNobel
Alternative cruise nameAkzoNobel
Cruise start date20210517
Who?
Data originatorHelmholtz Centre for Ocean Research Kiel
Data custodianHelmholtz Centre for Ocean Research Kiel
How to get data?
Data DistributorNational Institute of Oceanography and Applied Geophysics - OGS, Division of Oceanography
Database reference
Access/ordering of dataweb data access with registration
Access restriction
Other info
Quality info
NameDateComment
COMMISSION REGULATION (EC) No 1205/2008 of 3 December 2008 implementing Directive 2007/2/EC of the European Parliament and of the Council as regards metadata2008-12-04See the referenced specification
COMMISSION REGULATION (EU) No 1089/2010 of 23 November 2010 implementing Directive 2007/2/EC of the European Parliament and of the Council as regards interoperability of spatial data sets and services2010-12-08See the referenced specification
LineageThe data centres apply standard data quality control procedures on all data that the centres manage. Ask the data centre for details.
CDI-metadata
CDI-record id3319437
Version
CDI-record initial import date2022-01-11 13:21:57.137
CDI-record last update2023-08-08 16:39:37.667
Point of contactNational Institute of Oceanography and Applied Geophysics - OGS, Division of Oceanography
  • Close window